Our Product

พวกเรา คือทีมงานที่มีประสบการณ์ ผู้ซึ่งจะนำเสนอผลิตภัณฑ์ที่มีคุณภาพดีเยี่ยมทางด้านวิทยาการเจริญพันธุ์ในผู้มีบุตรยาก (A.R.T.) และด้าน Life Science เพื่อเติมเต็มความต้องการของท่าน

aithai thailand 6

About ARSCI

ARSCI Mission and Values

ARSCI Inc. aims to help you successfully achieve your goals. With a combination of efficiency in processes, effectiveness in production techniques and safety in quality control, ARSCI Inc. intends to assist and provide you with the best tools for an effortless and gratifying approach towards desired results.

We supply state of art devices all in one place for you to focus on creating life, and in turn making your life simple.

About Ellios Bio Tek

Ellios Bio Tek 

Founded in 1995 by Dr Bernard MONTANARI, ELLIOS BIO TEK designs disposable medical devices for assisted reproduction and functional exploration in gynaecology.

In addition, the company developed some specific food supplements for urology.

The products of ELLIOS BIO TEK, marketed in several countries, are widely used by clinicians and biologists specialised in human reproduction.

FAQ

Frequently Asked Questions

ทางลูกค้าจะสามารถติดตามความเคลื่อนไหวของพวกเรา รวมถึงข้อมูลที่น่าสนใจทางด้าน IVF และ Life Science ได้ทางช่องทางไหนได้บ้าง?

จากหน้าเวป หัวข้อ Blogs หรือ ทาง Facebook Fanpage (เร็วๆ นี้)ครับ

สามารถ ส่งของเร่งด่วนภายใน 1 วันได้หรือไม่ ?

สามารถจัดส่งให้ได้ ถ้ามีสินค้ารุ่นนั้นๆ ใน Stock ครับ

บริษัทของฉันสามารถ หัก ณ ที่จ่ายได้ไหม ?

ทางเราสามารถหัก ณ ที่จ่าย ได้แน่นอน และคุณลูกค้าต้องออกใบหัก ณ ที่จ่ายให้กับทางเรา

ลูกค้าสามารถขอใบเสนอราคาได้ที่หน้าเวปเลยไหม ?

ได้เลยครับ ที่หน้าเวป หัวข้อ Product แล้วเลือก Get Quotation

สามารถออกใบกำกับภาษีให้ได้ไหม ?

ได้แน่นอน บริษัทอ้ายไทย(ประเทศไทย)จำกัด ได้จด VAT เรียบร้อยแล้ว

สามารถฝึกอบรมถึงวิธีใช้งานผลิตภัณฑ์ได้ไหม ?

เรามีทีมวิทยากรพร้อมให้ความรู้เกี่ยวกับผลิตภัณฑ์ของบริษัทในทุกชิ้นที่ลูกค้าได้ทำการสั่งซื้อ*

ARSCI Brand

Catalog ID: I-30, I-35, I-45

Catalog ID: I-30, I-35, I-45

Injection or ICSI (Intracytoplasmic Sperm Injection) micropipettes are used to aspirate and inject sperm directly into the oocyte.

Wide selection of standard size injection micropipettes for different angles to accommodate user preferences.

State of the art production techniques generate

Accurate and consistent measurement specifications of inner diameter for quick and clean sperm transfer.

Smoothly polished opening to minimize trauma to oocyte during procedures.

*Available with spike and non-spike 

*Customization available with short turnaround time.

AH Pipette

Catalog ID: H-30, H-35, H-45

Holding micropipettes are used to secure and hold oocyte or embryo during ICSI and/or other procedures.

Selection of standard size and large size holding micropipettes with a variety of angle choices meet user preferences for handling oocytes or blastocysts.

Precise straight cut and evenly polished opening of micropipettes are ideal for holding without slip or damage to oocytes and blastocysts during procedures.

*Customization available with short turnaround time.

Catalog ID: D-120 to D-250

Catalog ID: D-120 to D-250

Denuding micropipettes are used to separate cumulus cells from the oocyte.

Wide range of Inner Diameter selections of micropipettes to accommodate user preferences.

Straight and flat openings are evenly polished with high precision techniques and thorough examination for smoothness, minimizing damages to oocyte during denudation.

*Customization available with short turnaround time.

*Holder and silicon bulbs used with denuding micropipettes are available separately.

Biopsy Pipette

Catalog ID: B-30, B-35, B-40

Biopsy micropipettes are used to remove a blastomere from a developing embryo for pre-implantation genetic diagnosis (PGD).

 

Wide selection of angles, diameters ranges, with flat and polished or beveled and polished features to meet user preferences.

Specialized techniques are applied to accomplish a perfectly even cut to minimize negative impacts on the oocyte.

*Customization available with short turnaround time.

Biopsy Pipette

Catalog ID: PB-30, PB-35, PB-45

Polar Body Biopsy micropipettes are used to remove the polar body of an oocyte for pre-implantation genetic diagnosis (PGD).

Wide selection of angles, flat and polished, to accommodate user preferences.

Openings are meticulously polished to perfection to minimize damage to oocyte

Customization available with short turnaround time.

AH Pipette

Catalog ID: PZD-30, PZD-35, PZD-45

Partial Zona Dissection (PZD) micropipettes are used in blastomere biopsy and hatching procedures by mechanically piercing the zona pellucida.

Different angle choices available to accommodate user preferences.

PZD micropipettes are dwindled meticulously to create a strong, sharp tip to facilitate clean and precise piercing of the oocyte or embryo.

*Customization available with short turnaround time.

AH Pipette

Catalog ID: I-30, I-35, I-45

Assisted Hatching (AH) micropipettes are used to chemically thin out and puncture the zona pellucida.

Different angle choices available to accommodate user preferences

Blunt and slightly polished opening helps the transfer of solutions easily without damage to the oocyte or embryo.

*Customization available with short turnaround time.

Catalog ID: TP-1200

Catalog ID: TP-1200

Transfer pipettes are made from borosilicate glass, carefully fired polished at one end to minimize any damage or negative impact on the substance being transferred.

Catalog ID: Silicon Bulb and JY Holder

Catalog ID: Silicon Bulb and JY Holder

Silicon Bulb and JY Holder are used with denuding micropipettes during denudation procedures.

Silicon bulbs are inserted in the holders and the denuding micropipettes are then connected to the bulbs.

Provide smooth and stable control with ease of use of micropipettes during procedures.

Catalog ID- JYS

Catalog ID- JYS

JY Straw is a safe water-proof system for storage of frozen oocyte or embryo. The system is easy to use and proven to maintain effectively a high survival rate of oocytes and embryos after thawing procedures.

Catalog ID- JY-O

Catalog ID- JY-O

Filtration technique of sterilization is used to produce a pure and light overlay for a stable pH, osmolality and temperature of culture media during IVF and micro-manipulating procedures.

 

Ellios-Biotek Brand

 

PMIU

Lenses

PMIU

Straight catheter for I.U.I

Product description

Distal P.E. tube with 2 lateral apertures at distal end.

Proximal P.P. graduated (cm) tube.

Indication

Intra uterine insemination

Recommandations for use

Before use, wash carefully the catheter with an appropriate sterile culture medium. 

Fill PMIU connected to a syringe with the sperm preparation. 

Push PMIU into the uterus. 

Push slowly the sperm preparation. 

Slowly withdraw the catheter.

ELLIOCATH®

EyeCare

ELLIOCATH®

Curved catheter for I.U.I

Product description

Curved transfer catheter making easier the passage through the cervical canal.

Arrows located on the grip of ELLIOCATH® indicate the direction of the curve of the catheter.

Indications

Embryo transfer.

Intra Uterine Insemination.

ELLIOCATH N.V.®

Exams

ELLIOCATH N.V.®

Embryo transfer catheter (metal free)

Product description

Curved transfer catheter making easier the passage through the cervical canal.

Tactile marks on the grip of ELLIOCATH N.V.® indicate the direction of the curve of the catheter.

Set of 4 labels for traceability.

Centimetric graduation on 360°.

Tight sliding ring.

Indications

Embryo transfer.

Intra Uterine Insemination.

Recommandations for use

Before use, wash carefully the catheter with an appropriate sterile culture medium.

Embryo transfer

Place the embryo in ELLIOCATH N.V.® with a small volume of culture medium.

Position the sliding ring according to the uterus depth previously measured.

Advance ELLIOCATH N.V.® to a distance 1 cm from the uterine fundus.

To facilitate cervical canal passage, push the catheter with a gentle rotational movement.

Transfer embryo.

Slowly withdraw the catheter.

Intra uterine insemination

Fill ELLIOCATH N.V.® , connected to a syringe, with the sperm preparation.

Push ELLIOCATH N.V.® into the uterus.

To facilitate cervical canal passage, push the catheter with a gentle rotational movement.

Push slowly the sperm preparation.

Slowly withdraw the catheter.

 

B2C

Lenses

B2C

Device for IUI at doctor’s office

Product description

A P.P. graduated sheath, with a small diameter P.E. distal part.

An acetal resin piston with a P.E. joint.

Indication

Intra uterine insemination at doctor’s office.

Recommandations for use

Before use, wash carefully the catheter with an appropriate sterile culture medium. 

Fill B2C with the sperm preparation (1 graduation = 100 µl). 

Insert slowly into the uterus. 

Push slowly the sperm preparation. 

Slowly withdraw the mini syringe.

OOCYTES ASPIRATION NEEDLE

EyeCare

OOCYTES ASPIRATION NEEDLE

Back cut bevel

Product description

Single lumen needle

Back-cut bevel

Non-Coring bevel

2 laser echo markings

Plastic stylet

Large ergonomic handle

Tactile mark indicating bevel position

4 tabs for traceability

Indications

Echoguided oocytes pick up.

Ovarian cyst aspiration.

*Recommandations for use

Before use, wash carefully the needle with an appropriate sterile culture medium. 

Adapt a syringe to the luer tip. 

Proceed according to the selected route.

OOCYTES PUNCTURE SET

Exams

OOCYTES PUNCTURE SET

for Falcon tube 14 ml

Production description

Single lumen needle.

Back-cut bevel.

Non-Coring bevel (prevents tissue entering lumen).

2 laser echo markings.

Tactile mark indicating bevel position.

2 tubes connected to a silicone stopper for 14 ml Falcon-like tube.

4 tabs for traceability.

Indications

Echoguided oocytes pick up

Ovarian Cyst aspiration

The oocytes puncture set with a 3 ways stopcock allows intermittent flushing and aspiration.

Recommandations for use

Before use, wash carefully the needle and the aspiration line with a appropriate sterile culture medium.

Connect a first Falcon-type sterile tube to the stopper (to be replaced when needed during the procedure).

Proceed to the ovum aspiration under controlled pressure.

Rinse out carefully once the aspiration is ended (oocytes, if present, will be collected from the needle and the aspiration line).

The oocytes puncture set with a 3 ways stopcock allows intermittent flushing and aspiration.

VIAL sv-XL30

Lenses

VIAL sv-XL30

For oocytes puncture set with screw cap

Product description

Specially designed to maintain follicular fluid temperature. When the vial is placed within a heat-controlled nest (Carteau & Ost, Labotect, etc…) the flange located at the upper part (diameter equal to the vial base) prevents outside air arrival potentially leading to turmoil and heat shocks detrimental to oocytes.

Cap and vial components selected to avoid any deformation at 37°C.

Cork designed to prevent leakings.

Handling easier with a quarter-turn screwthread.

ELLIOCATH®

EyeCare

ELLIOCATH N.V.®

Embryo transfer catheter (metal free)

Product description

An internal PEBD catheter.

A cone-shaped obturating ring.

A stiff external tube.

A two ways stopcock.

The cone-shaped obturator allows an effective and atraumatic occlusion of external cervical os whatever is the anatomic diameters (from 6 mm to 20 mm).

This device is sterilized by gamma radiation.

Indications

Sperm perfusion (Intra Uterine Insemination).

Hysterography.

Hyterosonography.

Methylene blue test.

Recommandations for use

Insert OLIVENNES Cath through the cervix into the uterus and push it till an effective occlusion is obtained.

Maintaining the catheter in position, inject slowly the preparation (sperm preparation, saline water, contrast medium).

Shut off the stopcock for the time necessary for the related procedure.

Remove slowly the device after completion of the procedure.

ELLIOCATH N.V.®

Exams

ELLIOCATH S®

Echogenic embryo transfer catheter

Product description

Precurved transfer catheter, with an atraumatic echogenic bulb tip:
– making easier passage through cervix,
– providing easy identification of its position.

Tactile marks on the grip indicating the direction of the curve of the catheter.

Adjustable positioner atraumatic easy to handle.

Set of 4 labels for traceability.

Indications

Embryo transfer.

Recommandations for use

Before use, wash carefully the catheter with an appropriate sterile culture medium.

Place the embryo in ELLIOCATH S® with a small volume of culture medium.

Position the sliding ring according to the uterus depth previously measured.

Advance ELLIOCATH S® to a distance 1 cm from the uterine fundus. To facilitate cervical canal passage, push the catheter with a gentle rotational movement.

Transfer embryo.

Slowly withdraw the catheter.

ELLIOSET

Lenses

ELLIOSET

Echogenic embryo transfer set

Product description

Guide catheter (soft P.P.)

Precurved, with an atraumatic echogenic bulb tip:
– making easier passage through cervix,
– providing easy identification of its position and atraumatic entry to cervical canal.

Adjustable positioner atraumatic easy to handle.

Grip shape facilitates introduction of the transfer catheter.

Transfer catheter (soft P.U.)

Echogenic tip.

Centimetric marks (on guide and transfer catheters) for confident placement of embryos.

Set of 4 labels for traceability.

Indications

Embryo transfer.

Recommandations for use

Before use, rinse carefully the embryo transfer catheter with an appropriate sterile culture medium.

Once embryos transfered, withdraw simultaneously and very slowly the 2 catheters.

ECHOCATH®

EyeCare

ECHOCATH®

Echogenic curved transfer catheter

Product description

Curved transfer catheter making easier the passage through the cervical canal

Arrows located on the grip of ECHOCATH® indicate the direction of the curve of the catheter

The echogenic distal end makes easy the positioning of ECHOCATH®

Indications

Embryo transfer

Intra Uterine Insemination

Recommandations for use

Before use, wash carefully the catheter with an appropriate sterile culture medium. 

 

Embryo transfer 

Place the embryo in ECHOCATH® with a small volume of culture medium. 

Position the sliding ring according to the uterus depth previously measured. 

Advance ECHOCATH® to a distance 1 cm from the uterine fundus. 

To facilitate cervical canal passage, push the catheter with a gentle rotational movement. 

Transfer embryo. 

Slowly withdraw the catheter. 

 

Intra uterine insemination 

Fill ECHOCATH® , connected to a syringe, with the sperm preparation. 

Advance ECHOCATH® to a distance 1 cm from the uterine fundus. 

To facilitate cervical canal passage, push the catheter with a gentle rotational movement. 

Push slowly the sperm preparation. Slowly withdraw the catheter.

EMBRYO TRANSFER SET

Exams

EMBRYO TRANSFER SET

Set for difficult embryo transfer

Product description

Guided catheter (polypropylene), with a sliding ring with centimetric graduations.

Malleable removable mandrel.

Transfer catheter (polyurethane) with centimetric graduations on the proximal part.

The proximal (luer) end of the guiding catheter has been specifically designed for making easier the transfer catheter insertion.

Indications

Embryo transfer in uterus, especially in the case of difficult transfers.

Intra Uterine Insemination.

Recommandations for use

Before use, wash carefully the embryo transfer set with an appropriate sterile culture medium.

With the help of centimetric graduations, position the sliding ring (guiding catheter) according to the uterus depth previously measured.

Give a shape if necessary to the guiding catheter + mandrel.

Cross the cervical canal up until the internal orifice.

Withdraw the mandrel.

Insert the transfer catheter into the guiding catheter and push it up until the first centimetric graduation reaches the guiding catheter entrance. Distal ends of both catheters match properly.

Then push the transfer catheter with the help of centimetric graduations and proceed to the embryo transfer.

Withdraw simultaneously and very slowly the 2 catheters.

SONOKAT

Lenses

SONOKAT

Hysterosonography

Product description

An internal PEBD catheter.

An obturating disk.

A stiff external tube.

A two ways stopcock.

The obturator allows an effective and atraumatic occlusion of external cervical os whatever is the anatomic diameters.

 

This device is sterilized by gamma radiation.

 

Indications

Hyterosonography

Recommandations for use 

Insert SONOKAT through the cervix into the uterus and push it till an effective occlusion is obtained.

Maintaining the catheter in position, inject slowly the preparation (saline water).

Shut off the stopcock for the time necessary for the related procedure.

Remove slowly the device after completion of the procedure.

HYSOKAT

EyeCare

HYSOKAT

Hysterosonography – Hystero-salpingo-foam-sonographie (HyFoSy)

Product description

HYSOKAT features specially developed to perform Hystero-salpingo-foam sonography or traditional hysterosonography:

o Central pre-curved soft catheter displaying:
– Centimetric graduations,
– Tactile marks on the grip indicating the direction of the curve.

o External sliding tube providing:
– A very soft and atraumatic cone at the distal end, for an effective and harmless occlusion of the cervix,
– A jointly fixed ring, at the proximal end for precise positioning.

Indications

Hysterosonography – Hystero-salpingo-foam-sonographie (HyFoSy).

Recommandations for use

Gently insert HYSOKAT through the cervix into the uterus.

Push the external tube forward until an effective occlusion is obtained.

Slowly inject the selected echogenic preparation.

Upon completion of the procedure, gently withdraw HYSOKAT and properly discard according to clinical waste treatment procedures.

ELLIOSAFE

Exams

ELLIOSAFE

Incubateur de transport

2 sondes de température 

Détection des anomalies

Mesure de la température au coeur de l’insert

Traçabilité des températures

Enregistrement des données à chaque minute

Mémorisation des données durant 10 jours

Données téléchargeables sur ordinateur

Autres informations

> Poids (avec batterie de base) : 3,9 Kg

> Dimensions (cm) : H=23, L=21, P=19

> Sélection parmi 3 inserts proposés

> Autonomie de la batterie : 1h30 (batteries avec plus grande autonomie en option : 4h, 8h et 12h)

> Temps de préchauffage : 1h30

> Réglage spécifique de température sur demande

> Affichage des températures

download brochure

รับใบเสนอราคา

Get a Quotation

Get Started

AITHAI Contact Detail

หมายเลขโทรศัพท์

อีเมล

info@aithaithailand.com

สำนักงาน

AITHAI (THAILAND) CO.,LTD.
เลขที่ 189/238 หมู่ 10 ตำบลวัดชลอ อำเภอบางกรวย จังหวัดนนทบุรี 11130

Email Us

info@aithaithailand.com

OFfice

AITHAI (THAILAND) CO.,LTD.

189/238 Moo 10,  Wat Chalo, Bang Kruai, Nonthaburi 11130